Light, infrared and distance sensors
How ambient light sensors match the eye, how infrared thermometers read temperature, how time-of-flight sensors time light, and how each misleads you.
Key points
- An ambient light sensor reports illuminance in lux, filtered to respond like the light-adapted eye: the CIE photopic function V(λ), defined from 360 to 830 nm and peaking at 555 nm. One maker lists display backlight control, lighting control systems and street lights as uses.123
- A bare silicon photodiode responds out to about 1100 nm, beyond what the eye sees, so sensors for visible light add a filter. One maker says most such sensors still read differently under different lamps, some because they do not stay at zero in the near infrared; its own may read a little high under halogen light.432
- A cover can make this worse: many dark windows dim visible light but pass infrared, raising the infrared share at the sensor. One maker says its sensor, with a half-sensitivity angle of about ±55°, must sit as close as possible under a large enough window to give results comparable to a reference light meter.23
- A non-contact infrared thermometer infers temperature from the infrared a surface emits, in a band such as 8 to 14 µm. It is generally calibrated on blackbody sources, with emissivity close to 1. A clean, polished metal has low emissivity, so it reads colder than it is unless the reading is corrected for it.56
- The distance-to-spot ratio (D:S) relates distance to the diameter of the spot holding a set share of the energy collected. The target must fill the field of view: one maker says 1 % to 35 % of the energy, by instrument quality, can come from outside the spot, and reflections from warm surroundings are collected too.6
- A time-of-flight distance sensor times how long its own light, usually near infrared, takes to reach a target and reflect back. One maker's single-zone sensor uses 940 nm light, ranges 20 to 2500 mm and is typically within ±5 % from 200 mm. Uses include robotics, automation, liquid level and camera autofocus.78910
- In one maker's datasheet, maximum range on an 18 % grey card falls from 2500 mm in 350 lux fluorescent light to 550 mm in 14 000 lux halogen light, once calibrated in the product, cover glass fitted, no target within 40 cm. The maker says shiny targets can cause multiple reflections; dark ones are less detectable.87
Common mistakes
- Hiding a light sensor under dark cover glass and trusting its lux. Many dark windows pass infrared, so the sensor sees a larger share of light the eye cannot see.
- Pointing an infrared thermometer at clean, polished metal and believing the number. Its low emissivity makes the surface read colder than it is.
- Testing a time-of-flight sensor on a grey card in dim light, then expecting the same range in bright halogen light, or skipping calibration behind its cover glass.
Spotted a mistake, or found this useful?
Tell usSources
- Mise en pratique for the definition of the candela and associated derived units for photometric and radiometric quantities in the SI (SI Brochure, 9th edition, Appendix 2, v1.02) · BIPM, Consultative Committee for Photometry and Radiometry (CCPR) · Standard
- OPT3001 Ambient Light Sensor (ALS) datasheet (SBOS681C) · Texas Instruments · Datasheet
- Designing the VEML7700 Into an Application (application note 84323) · Vishay Semiconductors · Reference
- Technical note: Si photodiodes (Cat. No. KSPD9001E04) · Hamamatsu Photonics · Reference
- What is emissivity and why is it important? · National Physical Laboratory (NPL, UK) · Reference
- Infrared Temperature Calibration 101 (application note) · Fluke · Vendor page
- Vertical measurement methods using direct time-of-flight (dToF) sensors (application note AN001102) · ams OSRAM · Reference
- TMF8801 Time-of-Flight Sensor datasheet (DS000648) · ams OSRAM · Datasheet
- TMF8801 1D time-of-flight sensor (product page) · ams OSRAM · Vendor page
- Time-of-Flight Camera – An Introduction (SLOA190B) · Texas Instruments · Reference