Sound sensors: microphones and sound level meters
What a MEMS microphone's sensitivity, SNR, overload point and frequency response mean, how sound level meters are classed and checked, and India's noise limits.
Key points
- A digital MEMS microphone delivers audio already digitised: for example as a PDM (pulse-density modulation) bit stream that a codec or host software must decimate, or, in one maker's I²S part with an on-chip ADC and decimation filters, as 24-bit I²S words a processor reads directly.12
- Two makers' MEMS microphone datasheets give sensitivity as the output for a 1 kHz tone at 94 dB SPL: in dBV for one's analog part (−38 dBV typical), in dBFS, relative to digital full scale, for the other's digital part (−26 dBFS ±1 dB). The latter defines 0 dBFS as a sine whose peaks just touch full scale.32
- One maker's I²S MEMS microphone, for wearables, IoT devices and teleconferencing, lists SNR 64 dBA and equivalent input noise 30 dBA SPL (A-weighted, 20 kHz bandwidth). Its acoustic overload point, where distortion reaches 10 % THD, is 120 dB SPL; its 90 dB dynamic range is derived from those two levels.2
- One maker's analog MEMS microphone gives its free-field frequency response normalised to 1 kHz; at 15 kHz its limits are 0 to +9 dB. The case matters too: another maker warns that a wide gasket between board and case may form a Helmholtz resonator, which may cause a high-frequency peak.34
- IEC 61672-1:2013's abstract gives two sound level meter classes; class 2 acceptance limits equal or exceed class 1's. IEC 60942:2017 field calibrators are class 1 or 2, class 1 mainly for class 1 meters. CPCB's protocol checks the meter with a calibrator before and after each session; readings must agree within 1.0 dB.567as of 19 November 2026
- Phone sound apps vary widely. In a 2014 NIOSH pilot in a reverberant chamber, only 10 of 130 iOS apps met the selection criteria, and three of those averaged within ±2 dBA of the reference; of 62 Android apps, 4 met them partly. A 2016 follow-up with external calibrated microphones came within ±1 dB.8
- India's Noise Pollution (Regulation and Control) Rules, 2000, as amended to 2017, limit ambient noise in dB(A) Leq, day/night: industrial 75/70, commercial 65/55, residential 55/45, silence zone 50/40; day is 6 a.m. to 10 p.m. CPCB's monitoring protocol calls for a Type 1 integrating meter (IEC 61672-1:2002 Class 1).9107as of 19 November 2026
Common mistakes
- Reading a digital microphone's −26 dBFS sensitivity without knowing its 0 dBFS. One maker defines 0 dBFS as a sine whose peaks just touch digital full scale.
- Trusting a phone app as a sound level meter. In NIOSH's pilot, 130 iOS apps were examined and 10 tested; only three averaged within ±2 dBA of the reference.
- Skipping the calibrator check after measuring. CPCB's protocol accepts results only if the checks before and after the session agree within 1.0 dB.
Where to go next
- On-device speech-to-text for VAHA: the model, where transcription happens, and a first accuracy test a whitepaper from our lab
- Wake-word and stop-phrase detection for VAHA: dataset, validation accuracy and first field check a whitepaper from our lab
Spotted a mistake, or found this useful?
Tell usSources
- MEMS Microphone Direct PDM Input via I2S to a C5515 EVM With Software Decimation (SPRAC51) · Texas Instruments · Reference
- ICS-43434 Multi-Mode Microphone with I2S Digital Output data sheet (DS-000069, revision 1.0) · TDK InvenSense (copy hosted by distributor CDI) · Datasheet
- IM73A135V01 IP57 dust and water resistant analog XENSIV MEMS microphone datasheet (V1.20, 2021-07-07) · Infineon Technologies AG · Datasheet
- Recommendations for Mounting and Connecting InvenSense MEMS Microphones (AN-1003, revision 1.0, 31 December 2013) · InvenSense, now TDK InvenSense (copy hosted by distributor CDI) · Reference
- IEC 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications (edition 2.0) · IEC · Standard
- IEC 60942:2017 Electroacoustics - Sound calibrators (edition 4.0) · IEC · Standard
- Protocol for Ambient Level Noise Monitoring · Central Pollution Control Board, Government of India (copy hosted by the Maharashtra Pollution Control Board) · Regulation
- So How Accurate Are These Smartphone Sound Measurement Apps? (C. A. Kardous and P. B. Shaw, 9 April 2014, with November 2016 and June 2018 updates) · National Institute for Occupational Safety and Health (NIOSH), US CDC · Reference
- The Noise Pollution (Regulation and Control) Rules, 2000 (S.O. 123(E), 14 February 2000, consolidated with amendments) · Central Pollution Control Board, Government of India · Regulation
- The Noise Pollution (Regulation and Control) Rules, 2000 (as amended to date; consolidated to S.O. 50(E), 11 January 2010) · Ministry of Environment, Forest and Climate Change, Government of India (PARIVESH portal) · Regulation