Sound sensors: microphones and sound level meters

What a MEMS microphone's sensitivity, SNR, overload point and frequency response mean, how sound level meters are classed and checked, and India's noise limits.

Core

Microphone levels, India's noise limits and the calibrator check One maker's MEMS microphone from its equivalent input noise to its acoustic overload point, India's ambient noise limits by zone for day and night, and a sound level meter measurement bracketed by calibrator checks. One maker's MEMS microphone 120 dB SPL overload point, 10 % THD 94 dB SPL, 1 kHz sensitivity tone: −26 dBFS out 90 dB dynamic range 30 dBA SPL equivalent input noise SNR 64 dBA (A-weighted) India's ambient noise limits dB(A) Leq; day 6 a.m. to 10 p.m. Day Night Industrial 75 70 Commercial 65 55 Residential 55 45 Silence zone 50 40 Checking a sound level meter Calibrator before Measure Type 1 meter Calibrator after Within 1.0 dB? results count Phone apps 3 of 10 iOS apps tested (130 examined) averaged within ±2 dBA Inside a case a wide gasket may form a Helmholtz resonator, which may cause a high-frequency peak Meter classes IEC 61672-1: class 1 or 2; class 2 limits equal or exceed class 1's
One maker's MEMS microphone levels, from equivalent input noise to overload; India's ambient noise limits; and the calibrator check that brackets a measurement.

Key points

  1. A digital MEMS microphone delivers audio already digitised: for example as a PDM (pulse-density modulation) bit stream that a codec or host software must decimate, or, in one maker's I²S part with an on-chip ADC and decimation filters, as 24-bit I²S words a processor reads directly.12
  2. Two makers' MEMS microphone datasheets give sensitivity as the output for a 1 kHz tone at 94 dB SPL: in dBV for one's analog part (−38 dBV typical), in dBFS, relative to digital full scale, for the other's digital part (−26 dBFS ±1 dB). The latter defines 0 dBFS as a sine whose peaks just touch full scale.32
  3. One maker's I²S MEMS microphone, for wearables, IoT devices and teleconferencing, lists SNR 64 dBA and equivalent input noise 30 dBA SPL (A-weighted, 20 kHz bandwidth). Its acoustic overload point, where distortion reaches 10 % THD, is 120 dB SPL; its 90 dB dynamic range is derived from those two levels.2
  4. One maker's analog MEMS microphone gives its free-field frequency response normalised to 1 kHz; at 15 kHz its limits are 0 to +9 dB. The case matters too: another maker warns that a wide gasket between board and case may form a Helmholtz resonator, which may cause a high-frequency peak.34
  5. IEC 61672-1:2013's abstract gives two sound level meter classes; class 2 acceptance limits equal or exceed class 1's. IEC 60942:2017 field calibrators are class 1 or 2, class 1 mainly for class 1 meters. CPCB's protocol checks the meter with a calibrator before and after each session; readings must agree within 1.0 dB.567as of 19 November 2026
  6. Phone sound apps vary widely. In a 2014 NIOSH pilot in a reverberant chamber, only 10 of 130 iOS apps met the selection criteria, and three of those averaged within ±2 dBA of the reference; of 62 Android apps, 4 met them partly. A 2016 follow-up with external calibrated microphones came within ±1 dB.8
  7. India's Noise Pollution (Regulation and Control) Rules, 2000, as amended to 2017, limit ambient noise in dB(A) Leq, day/night: industrial 75/70, commercial 65/55, residential 55/45, silence zone 50/40; day is 6 a.m. to 10 p.m. CPCB's monitoring protocol calls for a Type 1 integrating meter (IEC 61672-1:2002 Class 1).9107as of 19 November 2026

Common mistakes

  • Reading a digital microphone's −26 dBFS sensitivity without knowing its 0 dBFS. One maker defines 0 dBFS as a sine whose peaks just touch digital full scale.
  • Trusting a phone app as a sound level meter. In NIOSH's pilot, 130 iOS apps were examined and 10 tested; only three averaged within ±2 dBA of the reference.
  • Skipping the calibrator check after measuring. CPCB's protocol accepts results only if the checks before and after the session agree within 1.0 dB.

Sources

  1. MEMS Microphone Direct PDM Input via I2S to a C5515 EVM With Software Decimation (SPRAC51) · Texas Instruments · Reference
  2. ICS-43434 Multi-Mode Microphone with I2S Digital Output data sheet (DS-000069, revision 1.0) · TDK InvenSense (copy hosted by distributor CDI) · Datasheet
  3. IM73A135V01 IP57 dust and water resistant analog XENSIV MEMS microphone datasheet (V1.20, 2021-07-07) · Infineon Technologies AG · Datasheet
  4. Recommendations for Mounting and Connecting InvenSense MEMS Microphones (AN-1003, revision 1.0, 31 December 2013) · InvenSense, now TDK InvenSense (copy hosted by distributor CDI) · Reference
  5. IEC 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications (edition 2.0) · IEC · Standard
  6. IEC 60942:2017 Electroacoustics - Sound calibrators (edition 4.0) · IEC · Standard
  7. Protocol for Ambient Level Noise Monitoring · Central Pollution Control Board, Government of India (copy hosted by the Maharashtra Pollution Control Board) · Regulation
  8. So How Accurate Are These Smartphone Sound Measurement Apps? (C. A. Kardous and P. B. Shaw, 9 April 2014, with November 2016 and June 2018 updates) · National Institute for Occupational Safety and Health (NIOSH), US CDC · Reference
  9. The Noise Pollution (Regulation and Control) Rules, 2000 (S.O. 123(E), 14 February 2000, consolidated with amendments) · Central Pollution Control Board, Government of India · Regulation
  10. The Noise Pollution (Regulation and Control) Rules, 2000 (as amended to date; consolidated to S.O. 50(E), 11 January 2010) · Ministry of Environment, Forest and Climate Change, Government of India (PARIVESH portal) · Regulation