Motion and vibration sensors
How machine vibration is sensed with piezoelectric and MEMS accelerometers, how the sensor and its mounting can mislead you, and how to check a reading.
Key points
- MEMS inertial sensors combine an accelerometer (linear acceleration, including gravity) and a gyroscope (angular rate); a magnetometer is often added for heading. Gyroscope readings integrate into orientation that drifts over time without correction.1
- ISO 20816-3:2026, published in October 2026, is the current standard for evaluating vibration of industrial machines running at 120 r/min to 30 000 r/min, measured in situ on shafts, bearings, bearing pedestals or housings close to bearings. It replaces ISO 20816-3:2022, which replaced ISO 10816-3:2009.23as of 19 November 2026
- ISO 20816-3:2026 assesses vibration measured on shafts, bearings, bearing pedestals or housings close to bearings. On rotating machines, bearing housings are often good accelerometer spots: a short, rigid path, no gaskets. A small shift in position can change readings a lot at high frequencies.24
- One maker’s manual says the withdrawn DIN ISO 10816-3:2009 rated machines by RMS velocity in mm/s over 10 Hz to 1 000 Hz (2 Hz to 1 000 Hz below 600 r/min). Zone A was typical of newly commissioned machines, B usually fine for unrestricted continuous use, C usually unsuitable for it, and D may damage the machine.5as of 19 November 2026
- In India, BIS lists IS 14817 (Part 3):2017, identical to ISO 10816-3:2009 (industrial machines above 15 kW, 120 r/min to 15 000 r/min, measured in situ), as withdrawn and superseded by IS/ISO 20816-3:2022, which covers machines up to 30 000 r/min. Its committee is MED 28.67as of 19 November 2026
- A piezoelectric accelerometer has no true DC response: it makes charge only under dynamic forces. A MEMS variable-capacitance one reaches 0 Hz. In one maker's shaker test of three ±50 g sensors per type, MEMS ones were usable (±1 dB) to 3 kHz, piezoelectric ones beyond 10 kHz with about 9 times finer resolution.48
- A piezoelectric accelerometer's mounted resonance sets its upper frequency limit. One maker's handbook puts the error at 5 % at about 0.22 times that frequency, 10 % at about 0.30 times and 3 dB at about 0.54 times. Sensors built for very high frequencies are less sensitive; high-sensitivity ones cannot reach them.4
- How the sensor is attached changes that resonance. A stud on a smooth, clean surface gives the highest. Wax comes close but is limited to 40 °C, as it softens. A magnetic base adds mass and lowers it. A hand-held probe pulls it into the measured range, so one maker limits probes to quick spot checks below 1 000 Hz.49
- To check a vibration channel in the field, one maker's handbook describes a pocket-sized calibrated exciter giving 10 m/s² RMS at 159.2 Hz (1 000 rad/s), equal to 10 mm/s RMS velocity and 10 µm RMS displacement. Calibration compares a sensor back to back with a reference accelerometer on one vibration source.4
Common mistakes
- Holding an accelerometer on a hand-held probe and trusting readings above 1 000 Hz. The probe pulls the sensor's resonance down into the range you are measuring.
- Expecting a piezoelectric accelerometer to report steady acceleration. It has no true DC response; a MEMS variable-capacitance sensor responds down to 0 Hz.
- Using the ISO 10816-3:2009 zones (since superseded by ISO 20816-3) without matching their quantity and band: RMS velocity in mm/s over 10 Hz to 1 000 Hz.
Spotted a mistake, or found this useful?
Tell usSources
- BNO055 Intelligent 9-axis absolute orientation sensor datasheet (BST-BNO055-DS000) · Bosch Sensortec · Datasheet
- ISO 20816-3:2026 Mechanical vibration - Measurement and evaluation of machine vibration - Part 3: Industrial machines with operating speeds between 120 r/min and 30 000 r/min · ISO · Standard
- UNI ISO 20816-3:2023 (ISO 20816-3:2022) preview pages · UNI (Ente Italiano di Normazione) · Standard
- Piezoelectric Accelerometers and Vibration Preamplifiers: Theory and Application Handbook (BB0694, revision November 1987) · Brüel & Kjær · Reference
- TF3600 TwinCAT 3 Condition Monitoring: Vibration assessment · Beckhoff Automation · Reference
- IS 14817 (Part 3):2017 / ISO 10816-3:2009 Mechanical vibration: Evaluation of machine vibration by measurements on non-rotating parts, Part 3 (Know your standards record) · Bureau of Indian Standards · Standard
- IS/ISO 20816 search result (BIS e-Sale): IS/ISO 20816 (Part 3):2022 / ISO 20816-3:2022 · Bureau of Indian Standards (standards portal operated by BSB Edge) · Standard
- Vibration Sensor Technology in Predictive Maintenance Applications (white paper) · TE Connectivity · Vendor page
- Mounting/installing an accelerometer · Kistler · Vendor page