Air quality sensors: gases, VOCs, CO₂ and particles

How low-cost MOX gas, NDIR CO₂ and optical particle sensors work, what their numbers really are, and how each one can mislead you.

Core

Three low-cost air quality sensors: what each senses, reports and gets wrong A MOX gas sensor reports TVOC and eCO₂ estimates from a resistance change, an NDIR sensor measures CO₂ by infrared absorption at 4.26 µm, and an optical sensor estimates PM2.5 from scattered laser light. Each column shows how the reading can mislead, and the bottom row shows what to check it against and India's PM limits. MOX gas sensor heated tin dioxide hydrogen, ammonia, ethanol, toluene Tin dioxide resistance falls TVOC, eCO₂ calculated estimates Cross-sensitive responds to many gases; shifts with temperature and humidity; drops sharply after power-up NDIR CO₂ sensor infrared absorption absorbs 4.26 µm CO₂ source gas cell detector CO₂ in ppm measured by absorption Self-calibration takes the lowest level as 400 ppm. Buildings occupied round the clock may be 600 to 800 ppm Particle sensor laser light scattering particles laser detector PM2.5 in µg/m³ estimated from light Needs correcting one sensor read about 40 % high (raw) in an EPA study, more at higher humidity Check against a reference CO₂: a reference sensor or a known CO₂ level PM2.5: a collocated regulatory monitor India's NAAQS (CPCB, 2009) PM2.5: 40 µg/m³ annual, 60 µg/m³ 24-hour PM10: 60 µg/m³ annual, 100 µg/m³ 24-hour Methods: gravimetric, 'TOEM', beta attenuation
A MOX gas sensor, an NDIR CO₂ sensor and an optical particle sensor: what each senses, what it reports, how it misleads you, and what to check it against.

Key points

  1. A metal-oxide (MOX) gas sensor heats a semiconductor, typically tin dioxide, whose resistance falls as reducing gases react with oxygen on its surface. One sensor responds to many gases, such as hydrogen, ammonia, ethanol and toluene. They are used in air cleaners, ventilation control and air quality monitors.123
  2. In one maker's data, a MOX sensor's resistance in clean air changes with temperature and humidity, and drops sharply in the first seconds after power-up whatever gas is present, so the maker recommends a start-up delay. Its sensitivity data assume 2 days or more of preheating.2
  3. Some indoor air quality gas sensors report 'TVOC' and 'eCO₂' (or 'CO₂eq'), calculated by their own algorithms from raw gas signals. eCO₂ is a proxy for CO₂, estimated from VOC levels or from ethanol and hydrogen signals. One returns a fixed 400 ppm CO₂eq and 0 ppb TVOC for 15 s after its initialisation command.34
  4. An NDIR CO₂ sensor measures CO₂ by its infrared absorption at 4.26 µm. In a basic design, light crosses the gas to a detector and less gets through as CO₂ rises. No other commonly encountered gas absorbs there, so NDIR is highly selective. It is used to control ventilation in buildings.5678
  5. Some NDIR CO₂ sensors self-calibrate by taking the lowest level over several days, or a week, as outdoor air at 400 ppm. In buildings occupied round the clock, the lowest may be around 600 to 800 ppm, so the sensor rescales wrongly. Makers offer recalibration against a reference sensor or a known CO₂ level.698
  6. Optical particle sensors often need correcting, as aerosol properties and humidity vary. In an EPA study, raw 24-hour PM2.5 mass estimates from one widely used laser-scattering sensor were about 40 % high in most of the US, more at higher humidity; EPA fitted a correction using collocated regulatory monitors.10
  7. India's National Ambient Air Quality Standards (2009, still in force in 2026) set PM2.5 limits of 40 µg/m³ as an annual mean and 60 µg/m³ over 24 hours, and PM10 limits of 60 and 100 µg/m³. The measurement methods listed for both are gravimetric, 'TOEM' (as printed) and beta attenuation.111213as of 19 November 2026

Common mistakes

  • Treating eCO₂ or CO₂eq as a measured CO₂ level. It is a proxy estimated from a gas sensor's VOC, or ethanol and hydrogen, signals; an NDIR sensor measures CO₂ by its own absorption.
  • Leaving automatic self-calibration on in a building that is occupied round the clock, so the CO₂ sensor slowly learns the wrong baseline.
  • Comparing a few minutes of raw PM2.5 sensor readings with a 24-hour limit, with no correction for humidity.

Sources

  1. Operating principle: MOS type · Figaro Engineering Inc. · Vendor page
  2. Technical Information for TGS2602 (air quality control sensor), revised 09/24 · Figaro Engineering Inc. · Datasheet
  3. Datasheet SGP30: Indoor Air Quality Sensor for TVOC and CO2eq Measurements, version 1.0 (May 2020) · Sensirion AG · Datasheet
  4. Measure VOCs to maintain high indoor air quality (ENS160 technical article) · ScioSense B.V. · Vendor page
  5. Carbon Dioxide Sensing—Biomedical Applications to Human Subjects (Dervieux, Théron and Uhring, Sensors 22(1), 188, 2022) · MDPI, via PubMed Central (US National Library of Medicine) · Reference
  6. Infrared sensor technology and its impact on HVAC CO2 measurement accuracy (application note) · Vaisala · Vendor page
  7. Operating principle: NDIR type · Figaro Engineering Inc. · Vendor page
  8. SCD4x Datasheet, version 1.7 (April 2025) · Sensirion AG · Datasheet
  9. Field calibration for SCD30, version 0.2 (September 2018) · Sensirion AG · Reference
  10. Development and application of a United States-wide correction for PM2.5 data collected with the PurpleAir sensor (Barkjohn, Gantt and Clements, Atmos. Meas. Tech. 14, 4617-4637, 2021) · Copernicus Publications (authors: US Environmental Protection Agency) · Reference
  11. National Ambient Air Quality Standards, notification No. B-29016/20/90/PCI-L (Gazette of India Extraordinary, Part III Sec. 4, No. 217, 18 November 2009) · Central Pollution Control Board, Government of India · Regulation
  12. The Environment (Protection) Rules, 1986 (as amended to date), Schedule VII: National Ambient Air Quality Standards, substituted by G.S.R. 826(E), 16 November 2009 · Delhi Pollution Control Committee, Government of NCT of Delhi · Regulation
  13. Parliament Question: Impact of National Clean Air Programme on PM2.5 levels (Rajya Sabha unstarred Q545, written reply) · Press Information Bureau, Ministry of Environment, Forest and Climate Change · News